Building Regulations Part L

As with the 2006 edition Document L for England & Wales is split into 4 parts.
Please refer to Section 6 for details of the Building Standard Technical Handbook which is applicable to Scotland.

ADL1B – Existing dwellings, England & Wales

This is the document that covers domestic replacements and therefore will affect most fabricators for a majority of the windows and doors that they supply or install.


The requirements are summarised as follows:

Windows

  • Window Energy Rating minimum Band C
  • Whole element U-Value 1.6W/m²K or better

Doors

  • Whole element U-Value 1.8W/m²K or better

Conservatories

  • Exemption for sizes of less than 30m² remains providing they are at ground level, thermal separation between the existing building remains and the heating system is separate from main dwelling.

Extensions

  • No separate requirements for performance but sizes should not exceed 25% of floor area. Also a cautionary note that windows of less than 20% floor area can provide inadequate levels of daylight leading to additional use of artificial light.

ADL2B – Existing buildings other than dwellings, England & Wales

Windows

  • Whole element U-Value 1.8W/m²K or better
  • Window Energy Rating minimum Band C (windows domestic in character only)

Doors

  • Window Energy Rating minimum Band C (windows domestic in character only)
  • High usage entrance doors, 3.5W/m²K

Conservatories

  • Exempt if heating system is separate from main dwelling and thermal separation between the existing building remains.

Extensions

  • No separate requirements for performance but sizes should not exceed the following area of exposed wall;
    • 30% for residential buildings where people temporarily or permanently reside.
    • 40% for places of assembly, offices and shops.
    • 15% for industrial and storage buildings.
  • A centre pane U-Value of 1.2 Wm²k can be used to maintain the character and existing façade of a building where the above cannot be met.
  • WER schemes and U-Value calculations as per document L1B.
  • If a case can be made, buildings that may be subject to high internal gains can have their area weighted U-Values relaxed, however they must be no worse than 2.7W/m²K.

ADL1A – New dwellings, England & Wales

As with the existing method of compliance, the CO2 emissions associated with the energy consumption of the whole building remains as the sole criterion. The predicted rate of emissions (the Dwelling Emissions Rate) must not exceed the Target Emissions Rate (based on a notional dwelling). The standard government software, SAP, provides the means for demonstrating compliance.
There are backstop values that a window manufacturer needs to be aware of, but in practice the thermal performance requirements for the contract will be specified to meet the Dwellings Emissions Rate.

Windows, doors and curtain walling

  • Whole element U-Value 2.0Wm²k.

A cautionary note that windows of less than 20% floor area can provide inadequate levels of daylight leading to additional use of artificial light.

ADL2A – New buildings other than dwellings, England & Wales

As with the existing method of compliance, the CO2 emissions associated with the energy consumption of the whole building remains as the sole criterion. The predicted rate of emissions (the Building Emissions Rate) must not exceed the Target Emissions Rate (based on a notional dwelling). Approved Government software, SBEM, provides the means for demonstrating compliance.
There are backstop values that a window manufacturer needs to be aware of, but in practice the thermal performance requirements for the contract will be specified to meet the Buildings Emissions Rate.

Windows, doors and curtain walling

  • Whole element U-Value 2.2W/m²K.

High usage entrance doors

  • Whole element U-Value 3.5W/m²K.

If a case can be made, buildings that may be subject to high internal gains can have their area weighted U-Values relaxed, however they must be no worse than 2.7W/m²K.

Section 6 – Energy (Domestic), Scotland

The requirements for domestic windows & doors are as follows.

Windows and Doors (Replacement)

  • Area weighted U-Value 1.6W/m²K or better
  • Window Energy Rating minimum Band C.

Windows and Doors (New build)

  • Backstop values U-Value 1.8W/m²K or better

Extensions
Where existing building has walls 0.7 W/m²K and roof 0.25 W/m²K or <

  • Area weighted U-Value 1.6W/m²K or better Window
  • Energy Rating minimum Band C.

Extensions
Where existing building has walls > than 0.7W/m²K and roof 0.25 W/m²K

  • Area weighted U-Value 1.4W/m²K or better
  • Window Energy Rating Band A.

Conservatories

  • Area weighted U-Value 2.0W/m²K or better (frame/glazed elements)

Additional considerations;

  • Conversions of unheated buildings (including barn, garage, loft conversions) should be treated the same as extensions.
  • Windows in extensions should be limited to 25% of the extension floor area including any openings built over as a result.
  • U-Values for extensions may be varied providing that the area weighted value of all building elements is no greater than a notional extension.
  • Where 1 or 2 replacement windows/doors are installed to allow matching with existing building and here the above requirements cannot be met a centre pane U-Value of 1.2W/m²K may be used.
  • No minimum or maximum window sizes have been set for new build due to a balance required of innovative solutions between heat loss and solar gain along with natural and artificial light. This will be decided by the dwellings emission rate.
  • Conservatories are exempt from the Building Warrant if they do not exceed 8m², are thermally divided from the dwelling to the same level as other exposed elements, does not contain a flue, fixed combustion appliance, sanitary facility or located within 1 metre of a boundary.
  • Where alterations are carried out, attention should be paid to limiting thermal bridging around windows or doors.

Section 6 – Energy (Non-Domestic), Scotland

The requirements for domestic windows & doors are as follows.

Windows and Doors (Replacement)

  • Area weighted U-Value 1.6W/m²K or better

Windows and Doors (New build)

  • Backstop values U-Value 2.0W/m²K or better

Conversions of (Heated buildings)

  • Area weighted U-Value 1.6W/m²K or better

Shell buildings (for later fit out)

  • Area weighted U-Value 1.6W/m²K or better

Extensions

  • Area weighted U-Value 1.6W/m²K or better and sizes should not exceed the following area of exposed wall;
    • 40% for residential buildings, offices, shops, assembly and entertainment buildings.
    • 15% for industrial and storage units.
  • U-Values for extensions may be varied providing that the area weighted value of all building elements is no greater than a notional extension.
  • No minimum or maximum window sizes have been set for new build due to a balance required of innovative solutions between heat loss and solar gain along with natural and artificial light. This will be decided by the buildings emission rate.
  • Where 1 or 2 replacement windows/doors are installed a centre pane U-Value of 1.2W/m²K may be used.
  • With certain exceptions there are no U-Value requirements for display windows (e.g. shop fronts).